Safety Barriers

Product Details · PRODUCT DETAILS

LU-A12 Detection-End (Signal Input) Isolation Safety Barrier (1 In / 2 Out)

The LU-A12 supplies power to field transmitters, limits hazardous energy from entering the hazardous area through the intrinsically safe terminals, and converts DC signals into two mutually isolated standard process signals. It connects two- or three-wire transmitters and is powered by an independent supply with isolation between supply, input and output.

  • CategorySafety Barriers
  • Model-
  • Views8379 views
  • Updated2011-11-25
Selection customization and technical solution support available. After-sales Service 0086-400-8875-999, Pre-sales Hotline 0086-0592-5711111

I. Overview

● The LU-A12 supplies power to field transmitters, limits hazardous energy from entering the hazardous location through the intrinsically safe terminals, and converts DC signals into two mutually isolated standard process signals.

● Can be connected to two-/three-wire transmitters.

● Powered by an independent power supply, with isolation between power supply, input and output.

II. Technical parameters

●Input parameters (hazardous area signals)

For current input  Input range: 4~20mA, 0~20mA, 0~10mA

Distribution voltage: ≥16VDC

Input resistance: built-in input resistor 50Ω

For voltage input  Input range: 1~5V, 0~5V, 0~10V

Input impedance: ≥500KΩ

Thermocouple input (millivolt signal), input range:

Graduation

Measuring range (°C)

Minimum span (°C)

K

0-1300

120

E

0-1000

80

S

0-1600

580

B

400-1800

1000

R

0-1600

850

T

-200-400

120

N

0-1200

180

W

0-2300

340

J

0-1200

100

  

Minimum millivolt span: 3mV

RTD input, input range:

Graduation

Measuring range (°C)

Minimum span (°C)

Cu50

-50-150

50

Cu100

-50-150

50

Pt10

-200-600

200

Pt100

-200-800

50

Permissible lead resistance : ≤5Ω (identical for the three wires)

●Output parameters (safe area signals)

For current output  Output range: 4~20mA, 0~20mA, 0~10mA

    Permissible load: ≤350Ω

For voltage output  Output range: 1~5V, 0~5V, 0~10V

          Output impedance: ≤500Ω

●Intrinsic safety parameters

Linear current/voltage                      Thermocouple/RTD

Explosion-proof marking: [Exia] ⅡC           Explosion-proof marking: [Exia] ⅡC

  Maximum permissible voltage Um: 250V         Maximum permissible voltage Um: 250V

  Maximum output voltage Uo: 28V           Maximum output voltage Uo: 12V

Maximum output current Io: 93mA          Maximum output current Io: 24mA

● Ambient parameters

Power sup ply: 20-30VDC

Ripple factor below 10%P-P, approx. 1W 

Power indicator lamp: green LED, lit when the power is supplied

Operating temperature range: -20~ +60°C

Operating humidity range: 0 ~ 95%RH (non-condensing)

● General technical parameters

Standard accuracy: ±0.1%

Temperature drift: ±0.015%/°C

Response time: ≤10mS

Insulation resistance: 2.5KV, 1min, 50HZ between input, output and power supply

Isolation strength: input-output-power supply ≥100MΩ/500VDC

Effect of load resistance variation: ±0.1%/250Ω (for current output)

                   ±0.1% (for voltage output)

Power-on stabilization time: ≤3s

LU-A12 Detection-End (Signal Input) Isolation Safety Barrier (1 In / 2 Out) Selection Guide