1. summary:
LU-L adopts proliferate silicon pressure sensors groupware which produced by famous NovaSensor, American company and with high accuracy & high stability. Through high stability amplifier electric circuit and accurate temperature compensation, it can transfer the measured liquid signal to 4~20mADC standard electric signal.
Exquisite seal technology and perfect installation process can insure the high quality & best performance. LU-L have two structure types: one-body type and separated-body type, and according to measured mediums, there are electric cable type, armored type and anti-corrosive type. Armored type and anti-corrosive type can resist corrasion of several kinds of corrosive liquid, can widely suit for user’s requirement.
LU-L have two types: common type and intrinsically-safety & explosion-proof type. Explosion-proof type can be used to each kind of execrable or hazardous industrial field.
2.characteristic:
·0~0.3m to 0~350m,
·one-body type and separated-body type,
·electric cable type, armored type and anti-corrosive type,
·prevent lightning strike and radio disturbance,
·reverse polarity protection and current-limit protection,
·Intrinsically-safety & Explosion-proof,
·zero & span external continually adjusted,
·High accuracy, high stability and high reliability.
3. applicant:
·liquid survey and control of industry field,
·hydrology survey and control,
·Navigation and shipping manufacture,
·City water supply & sewage dealing with,
·Great river & dam and irrigation water construction,
·Gas separate device and thermal motors,
·Food and soft drink device,
·Chemical and hospital device,
4.technical index
·Measured medium:
Water and common non-corrosive liquid (electric cable type);
Each kind of liquid which compatible to
Each kind of corrosive liquid (anti-corrosive type);
·range ability: 0~0.3m to 0~350m,
·over-load pressure: 2 times of max. range,
·output: 4-20mA DC (2-wires)
·working voltage: 14~36VDC (2-wires), standard 24VDC±5%, Wpp<1%,
·medium temperature: -25 ~ +100℃,
·environment temperature: -20 ~ +85℃
·Load resistance: (4~20mA): R =(U-14)/0.02-R0, [U is power voltage, R0 is electric cable inner resistance], (0~10mA): R≤1KΩ,(0~5V): R≥300Ω
5. performance index
·Accuracy: ±0.25%, including the synthesize errors of non-linear, repeat and return difference.
·Zero error: ≤±0.5% of output range (only for one-body type),
( zero error is adjusted for separated-body type);
·zero shift: 0~+80% of the max. range (only for separated-body type),
(no zero shift for one-body type)
·range adjustment: can willfully adjust between the min. and max. ranges (only for separated-body type),
(range could not be adjusted for one-body type)
·Over-pressure affect: <0.25% of max. range
·Power affect: <0.01% of output range
·Load affect: can be neglected
·Temperature affect: ±1.5% of max. range (temperature –20~85℃, including zero & span affections)
·Stability: ±0.25% of max. range (12 months)
6. structure index:
·Diaphragm material: 316L stainless steel (for electric cable type and armored type);
Ceramic (for anti-corrosive type)
·detection head material: 1Cr18Ni9Ti (for electric cable type and armored type);
PTFE. (for anti-corrosive type)
·lead-out line: ventilate cable which outer diameter Φ9, double layer, wearable and water-proof (electric cable type);
armored pipe which outer diameter Φ6, stainless steel (armored type);
PTFE. Soft pipe which outer diameter Φ7.5 (anti-corrosive type);
·line connection box: aluminum alloy with plastic-spouted around the surface,
·indicate meter: 0~100% linear indication (analog meter, only separated-body type);
3-1/2 LCD digit display (digit display meter, only separated-body type);
·explosion-proof: Instrinsically-safety: Ex ia Ⅱ CT5;