Products > Industrial Intelligent Instruments > Pressure Transmitter > LU-CDP/GP remote flange diaphragm differential-pressure transmitter

LU-CDP/GP remote flange diaphragm differential-pressure transmitter

1.characteristic:

   LU-CDP/GP is to avoid the measured medium touch directly with the isolating diaphragm of flange.

   Remote transmitter is suit for the under industrial conditions:

·high temperature medium need to be isolated to the transmitter.

·Measured medium is corrosive to sensitive parts of the transmitter.

·Floating liquid or high viscosity medium.

·Measured medium becomes solid or crystal due to the environment or flow temperature changes.

·Need to strict clean the measuring head when change the measured medium.

·Measuring head need to be keep clean and sanitary.

·Measured Liquid which in seal pressure container.

 

2. technical performance

·to subject: liquid with corrosive or glutinous,

·range ability: 

remote double-flat flange:

LU-CDPS-4420

0-6-36Kpa

LU-CDPS-4520

0-30-180Kpa

LU-CDPS-4620

0-160-1000Kpa

LU-CDPS-4720

0-400-2500Kpa

 

remote single-flat flange (pressure type):

                 

LU-CGPS-1410

0-6-36Kpa

LU-CGPS-1510

0-30-180Kpa

LU-CGPS-1610

0-160-1000Kpa

LU-CGPS-1710

0-400-2500Kpa

LU-CGPS-1810

0-1600-10000Kpa

 

 

 

 

remote one-flat & one-in-line flange:

 

LU-CDPS-4350

0-1.2-7.2Kpa

LU-CDPS-4450

0-6-36Kpa

LU-CDPS-4550

0-30-180Kpa

LU-CDPS-4650

0-160-1000Kpa

LU-CDPS-4750

0-400-2500Kpa

 

remote single-in-line flange (pressure type):

 

LU-CGPS-1330

0-1.2-7.2Kpa

LU-CGPS-1430

0-6-36Kpa

LU-CGPS-1530

0-30-180KPa

LU-CGPS-1630

0-160-1000Kpa

LU-CGPS-1730

0-400-2500Kpa

LU-CGPS-1830

0-1600-10000Kpa

 

·output: 4-20mA DC

·power: 24VDC, it may be 12VDC if non-load, max. is 45VDC

·positive & negative transfer: up and low may not exceed the range limit after positive & negative transfer, whatever the output is.

Max. positive transfer: 500% of the min. span.

Max. negative transfer: 600% of the min. span.

·Temperature:

temperature of operating for amplifier: -25 +90

temperature of operating for sensor:  -40 +104

·Relative humidity: 0~100%

·Indicate meter : grade: 2.5

·Isolating explosion: ds BT5,   Instrinsically-safety: ia CT5

·Span & Zero: external continually adjusted

·Operating temperature of filled liquid of remote device

Silicon oil: -29 ~ +149

Inert oil: -18 ~ +204

·Pressure limit:

screw thread type: 14Mpa;

flange type: flange rated pressure;

clip loop type: 2Mpa;

flat type: flange rated pressure;

·Settling time: 2s. Response time is relative to temperature, pressure, remote method, capillary length and filled liquid.

 

3. performance index (note: test under the condition of none shift, capillary length 1.5m, filled silicon oil, 316L stainless isolating diaphragm)

·Temperature affect (remote device, capillary length 1.5m on one side):

       flat type & clip loop type: error < 0.62Kpa/55, the error will add 0.2Kpa if the filled silicon oil capillary length add 1.5m.

        screw thread type & flange type: error < 1.99Kpa/55, the error will add 0.2Kpa if the filled silicon oil capillary length add 1.5m.

·Over-pressure affect: ±0.25% of max. range (according to permitted over-loads for     different ranges)

·Power affect: <0.005%/V of output range

·Load affect: none affect when voltage >12VDC input to the transmitter.

·Mounting position affect: may cause zero error max. 250Pa, but can be calibrated, no affection for range. No affection if transmitter main body turn relative to flange. Need to positive transfer or negative transfer if the remote flange higher or lower than the transmitter main body. Average temperature will cause synthesize affection to the process, environment temperature will affect the total volume of filled liquid.

4. structure index:

·Structure material: diaphragm & vent / drain valve: 316 stainless steel;

                  Flange on remote side: carbon steel plating with cadmium, or 316 stainless steel

Flange & bolt: carbon steel plating with cadmium;

Fill liquid: silicon oil or inert liquid;

O ring: Fluorin rubber;

Electric shell: low-Cu & aluminum alloy

·electric parts connector: NPT 1/2 inner screw thread;

·net weight: transmitter main body 2.4kg,

(to remote measuring head & capillary, different type for different net weight)

After-sale service Pre sales consultation

Login  |  Register  Please login to ask question!




  • LU-L proliferate silicon liquid-level transmitter

  • LU-K proliferate silicon pressure transmitter