LU-S14000 Series I/O Modules

Product Details · PRODUCT DETAILS

LU-S14520 Isolated RS232 to RS485 Converter Module

Model: LU-S14520 Isolated RS232 to RS485 Converter Module

The LU-S14520 is an isolated RS232-to-RS485 converter providing 3000VDC isolation protection. It handles 485 bus control automatically, supports multiple baud rates with auto-detection, and offers transmission rates up to 115.2 kbps. The bus includes transient interference suppression and lightning protection. Highlights include strong EMC immunity: air discharge +/-12KV and contact discharge +/-6KV.

  • CategoryLU-S14000 Series I/O Modules
  • ModelLU-S14520 Isolated RS232 to RS485 Converter Module
  • Views7219 views
  • Updated2011-11-25
Selection customization and technical solution support available. After-sales Service 0086-400-8875-999, Pre-sales Hotline 0086-0592-5711111

Overview
LU-S14520 is an isolated RS232-to-RS485 converter that provides 3000 VDC isolation protection, automatically manages the 485 bus internally, supports multiple baud rates with automatic detection, and achieves a transmission rate of up to 115.2 kbps. It features transient interference suppression and lightning protection on the bus.

Main features:
Superior immunity to interference (EMC)
•High ESD immunity Test results: air discharge ±12KV; contact discharge ±6KV
•Easily passes 3KV fast transient burst interference (EFT test)
•Lightning surge impact protection ±2KV
•Radiated noise immunity test An analog noise interference source is provided through a winding (Impulse voltage: 1KV, Impulse width: 1us); no abnormality after 10 min of application
•Voltage dips, short interruptions and voltage variation immunity test Power supply ramp ±20%Ut, time ramp 2s±20% Voltage dip and temporary interruption 40%Ut, duration 5s

Relay output
•Input: RS-232
•RS-232 interface: DB-9 connector
•Output: RS-485 (2-wire)
•RS-485 interface: plug-in screw terminals
•Speed (bps): 1200, 2400, 4800, 9600, 19.2k, 38.4k, 7.6k, 115.2k
•Isolation voltage: 3000VDC
•Automatic internal RS-485 bus management
•RS-485 requires no external data flow control signal
•Transient interference suppression on RS-485 data lines
•Networking distance up to 4000 ft

Power supply
•Power requirement: +10~+30Vdc (unregulated)
•Power consumption: 1.2W

 

LU-S14520 Isolated RS232 to RS485 Converter Module Selection Guide

Click to download the product manual. If the download fails, please contact customer service.

Download Now
RELATED PRODUCTS

Related Products

View Related Products

Need technical specifications and a quotation for this product?

Submit your request and our engineers will contact you within one business day.