LU-S14000 Series I/O Modules

Product Details · PRODUCT DETAILS

LU-S14013 Three-Channel RTD Input Module

The LU-S14013 is a 16-bit A/D three-channel RTD input module that acquires two-, three- or four-wire RTD signals. It supports PT10, PT100, PT200, PT500, PT1000, CU50 and CU100 RTDs with broken-wire detection. 2500V isolation between the analog input channels and the module protects against high-voltage surges. Modbus protocol is supported.

  • CategoryLU-S14000 Series I/O Modules
  • Model-
  • Views6711 views
  • Updated2026-10-27
Selection customization and technical solution support available. After-sales Service 0086-400-8875-999, Pre-sales Hotline 0086-0592-5711111

Overview
LU-S14013 is a 16-bit A/D three-channel RTD input module that can acquire two-wire, three-wire or four-wire RTD input signals. It supports acquisition of multiple RTDs including PT10, PT100, PT200, PT500, PT1000, CU50 and CU100, and provides broken-wire detection. A voltage isolation of 2500V is provided between the analog input channels and the module, effectively preventing the module from being damaged by high-voltage surges. It supports the Modbus protocol and uses the RS-485 bus for communication transmission, with a built-in optocoupler providing 3000V isolation voltage. It features surge protection, spike absorption and lightning protection.

Main features
Superior immunity to interference (EMC)
• High ESD immunity Test results: air discharge ±12KV; contact discharge ±6KV
• Easily passes 3KV fast transient burst interference (EFT test)
• Lightning surge impact protection ±2KV
• Radiated noise immunity test An analog noise interference source is provided through a winding (Impulse voltage: 1KV, Impulse width: 1us); no abnormality after 10 min of application
• Voltage dips, short interruptions and voltage variation immunity test Power supply ramp ±20%Ut, time ramp 2s±20% Voltage dip and temporary interruption 40%Ut, duration 5s

Analog input
• Effective resolution: 16 bits
• RTD types and temperature ranges
Type Test temperature RTD TCR Accuracy
Pt10 -200°C~+800°C Pt100 0.003851 0.05% or better
Pt200 0.003816
Pt500 0.003850
Pt1000 0.003910
Cu50 -50°C~+150°C 0.1% or better
Cu100
• Isolation voltage: 2500Vdc
• Sampling rate: 10 samples/s
• Input impedance: 20MΩ
• Input surge protection: yes
• Bandwidth: 2.62Hz
• Input wiring: 2-, 3- or 4-wire
• Zero drift: ±3μV/°C
• Full-scale drift: ±25ppm/°C
• CMR @ 50 / 60Hz: 150dB
• NMR @ 50 / 60Hz: 100dB

Communication
• Mode: RS-485
• Protocol: Modbus
• Isolation voltage: 3000Vdc
• Surge protection, lightning protection: yes

Built-in watchdog timer
Power supply
• Power requirement: +10~+30Vdc (unregulated)
• Power consumption: 1.6W

 

LU-S14013 Three-Channel RTD Input Module Selection Guide

Click to download the product manual. If the download fails, please contact customer service.

Download Now
RELATED PRODUCTS

Related Products

View Related Products

Need technical specifications and a quotation for this product?

Submit your request and our engineers will contact you within one business day.