Paperless Recorders

Product Details · PRODUCT DETAILS

LU-R/C 1300 Color Screen Display Process Control Paperless Recorder

The LU-R/C 1300 series intelligent paperless recorder combines recording and control in one unit, with universal full-switching inputs for thermocouples, RTDs, standard voltage and standard current signals. Output control modes include PID, on/off, auto-tuning and manual control.

  • CategoryPaperless Recorders
  • Model-
  • Views7463 views
  • Updated2026-03-23
Selection customization and technical solution support available. After-sales Service 0086-400-8875-999, Pre-sales Hotline 0086-0592-5711111

 LU-R/C 1300 series features

 
Combines recording and control in a single unit, with fully switchable universal input: supports thermocouple, RTD, standard voltage, standard current and other signals; output control modes include PID control, on/off control, auto-tuning control and manual control. It can accept 1 to 2 PID control channels or 1 to 4 signal inputs; each control board has independent signal input, main output and alarm output, with full isolation between inputs and outputs.
Programmable PID control with program curves of up to 100 segments; transmitter supply output is available.
 
Data storage: 64M built-in storage space, with each channel's recording interval independently adjustable from 1 to 3600 seconds; a high-capacity FLASH memory chip stores historical data with retention after power failure, and the internal storage time is 191 days to 1882 years; USB interface support allows data to be transferred to a USB flash drive to extend recording time.
 
Communication: the RS232 interface can connect to a portable computer or PDA to upload real-time/historical data, and the data can be analyzed, archived and printed via host computer software or USB flash drive utility software; the RS485 interface can connect to professional SCADA systems such as KingView and MCGS.
 
Display: supports overview, extra-large, bar graph, real-time curve, historical curve, alarm, system configuration, channel configuration and print setting screens; curve screens feature zooming, fully automatic playback of historical trends, time and amplitude zoom, and positioned queries of data for a specific year/month/day/hour/minute/second; channel tag names can be customized.
 
Hardware design: modular design for flexible configuration; different acquisition boards can be used simultaneously; complete electrical isolation between inputs and outputs reduces power supply radiation interference and improves reliability.
 
Operator interface: user-friendly HMI with operating hints on every screen, allowing operation without professional training; Chinese/English bilingual display interface.
 
 
System operating parameters
 
Sampling cycle: 0.5 s; basic error: ±0.2% F.S; real-time engineering value display accuracy: ±0.2% F.S; curve display accuracy: ±0.2% F.S; recall accuracy: ±0.2% F.S; bar graph: ±0.2% F.S; switching power supply: 85-264VAC, 12W, 50Hz±1Hz; or 24VDC.
 
Measurement input signal parameters
 
Input signal types: 0~10mADC, 4~20mADC, 0~5VDC, 1~5VDC, thermocouples (B, E, J, K, S, T, Wre325, N), RTDs (Pt100, Cu50, Cu100); flow/pressure signals: 0-10mADC, 4-20mADC.
Ranges of each signal type:
Type II: 0~10mADC, 0~5VDC; Type III: 4~20mADC, 1~5VDC
K-type thermocouple: 0°C~1300°C; S-type thermocouple: 0°C~1700°C; B-type thermocouple: 0°C~1800°C; T-type thermocouple: -200°C~400°C; E-type thermocouple: -200°C~1000°C; J-type thermocouple: 0°C~800°C; Wre325-type thermocouple: 0°C~2300°C; N-type thermocouple: 0°C~1300°C
Pt100:-200°C~600°C;Cu50:-50°C~150°C;Cu100:-50°C~150°C
 
Input impedance: current 250Ω; voltage 650KΩ; RTD requires three-wire resistance balance, lead resistance < 10Ω.
Input channels: 1-4 channels, each channel can accept a different signal type.
Thermocouple cold junction compensation error: ±1°C.
 
Output signal parameters
 
Output modes:
 
Current output: 0-10mADC (RL<1000Ω, extendable to 2000Ω); 0-20mADC (RL<500Ω, extendable to 1000Ω); 0-22mADC custom current (freely set by software).
Other outputs: solid-state relay drive (12V/50mADC); relay contact output; SCR zero-crossing trigger output (single-phase, three-phase); 24V power distribution (current < 200mADC).

LU-R/C 1300 Color Screen Display Process Control Paperless Recorder User Manual

Click to download the product manual. If the download fails, please contact customer service.

Download Now